Home
Characteristics
Quick Facts
Data Acquisition
Gallery
Data Acquisition and Processing
Steady-State Data System
Sytem: Analog. Number of Channels: 48. Sample Frequency: 1000Hz.
Sytem: Digital Input. Number of Channels: 16. Sample Frequency: Test Dependent.
Sytem: Force Balances. Number of Channels: 32. Sample Frequency: 1000Hz.
Sytem: Pressures. Number of Channels: 2048. Sample Frequency: 20Hz.
Sytem: Temperatures. Number of Channels: 60. Sample Frequency: 100Hz.
Time Variant Data System (High Speed)
Sytem: Analog Channels. Number of Channels: 160. Sample Frequency: 20 KHz bandwidth.
Sytem: Force Balance Channels. Number of Channels: 160. Sample Frequency: 80 KHz bandwidth.
Classified Capability Available (Secret/SAR)
Instrumentation
Strain Gauge Balances: 6-component (full-span)
Angle-of-Attack (AOA) Accelerometers: ±15° with offsets to +45°
Available Corrections:
Interactions
Temperature effects
Attitude tares
Axes orientation
Pressure tares
Momentum (flow) tares
Wall Interference
11-Foot Transonic Unitary Plan Facility Fact Sheet