Probe 1 took data upstream on the fuselage nose and near the wing leading edge.
Probe 2 took data in the juncture region over the rear part of the wing.

Note that Probe 1 was operational during Tests 638 and 640, but the laser failed in Test 653.
Probe 2 was operational for all three tests.

Reminder: Test 638 used F6-based wing WITHOUT horn (i.e., no L.E. extension or fillet)
          Test 640 and 653 used F6-based wing WITH horn
Data were taken only at alpha=5 deg and -2.5 deg in Tests 638 and 640.
Data were taken at alpha=7.5 deg, 5 deg, and -2.5 deg in Test 653.

Directories:
LDV_Probe_1 - LDV data on the nose and L.E. region of the wing
LDV_Probe_2 - LDV data on the T.E. region of the wing