Holden Run Nominal Conditions

Run # | U,m/s | Mach#| Rho,Kg/m3 | Tinf | TWall | Wedge  | Xc, Corner | Wedge_XLength |  Flow Type
                                                | Angle  | Location   | from Corner   |
                                                         |from PlateLE| along plate   |
 12   | 1390  |  8.2 | 0.5090   | 71.1K | 296K  | 27 deg | 39.2 inch  | 12"           M8 Turbulent Compression Corner
 16   | 1375  |  8.3 | 0.5060   | 68.9K | 296K  | 30 deg | 39.2 inch  | 12"           M8 Turbulent Compression Corner
 19   | 1379  |  8.1 | 0.4910   | 71.7K | 297K  | 33 deg | 39.2 inch  | 12"           M8 Turbulent Compression Corner
 24   | 1378  |  8.2 | 0.4990   | 70.0K | 298K  | 36 deg | 39.2 inch  | 12"           M8 Turbulent Compression Corner
 M8FP | 1411  |  8.32| 0.7009   | 71.1K | 294K  |                                     Mach 8 Turbulent Flat Plate

 54   | 1769  | 11.3 | 0.08246  | 61.0K | 300K  | 36 deg | 40.3 inch  | 12"           M11 Turbulent Compression Corner
 22   | 1905  | 11.7 | 0.00141  | 66.0K |       | 12 deg | 17.3 inch  | 13"           M11 Laminar Compression Corner

  7   | 1780  | 11.1 | 0.09483  | 64.0K |       |                                     Mach 11 Turbulent Flat Plate
 10   | 1739  | 10.6 | 0.09637  | 67.0K |       |                                     Mach 11 Turbulent Flat Plate

 44   | 1905  | 11.7 | 0.00139  | 66.0K |       |     5 deg ShockGen                  Mach 11 Laminar Impinging Shock
 49   | 1814  | 11.4 | 0.08910  | 63.0K |       |    20 deg ShockGen                  Mach 11 Turbulent Impinging Shock
 
Impinging Shock Geometry
Distances from FlatPlate Leading Edge

Run  |ShockGenAngle|  XGenLE  | YGenLE | XGenTE  | YGenTE | PlateLength
44   |    5 deg    |  -5.091" | 3.779" | 15.062" | 2.016" | 30.0"        Mach 11 Laminar Impinging Shock
49   |   20 deg    |   17.79" | 9.919" | 36.8"   | 3.000" | 50.0"        Mach 11 Turbulent Impinging Shock