SUMMARY OF KSC SEGMENT ASSEMBLY OPERATIONS RH AFT (SRM-25) TO RH AFT CENTER (SRM-26) | ||
|---|---|---|
|
| ||
|
SEGMENT STACK SEQUENCE - 7 DEC 85 | ||
|
| ||
|
ACTIVITY |
TIME |
REMARKS |
|
| ||
|
POSITION RH AFT CENTER SEGMENT IN TRANSFER AISLE |
2300 |
6 DEC 85 |
|
LIFTING BEAM CONNECTED |
0100 |
-- |
|
JOINT PUTTY APPLICATION COMPLETE |
0120 |
|
|
FIRST ROUNDNESS MEASUREMENT - 4-POINT LIFT |
0145 |
UNACCEPTABLE |
|
FIRST ROUNDNESS MEASUREMENT - 2-POINT LIFT |
0300 |
UNACCEPTABLE |
|
SECOND ROUNDNESS MEASUREMENT - 2-POINT LIFT |
0354 |
UNACCEPTABLE |
|
THIRD ROUNDNESS MEASUREMENT - 2-POINT LIFT |
0415 |
UNACCEPTABLE |
|
COMPLETE RH AFT CENTER TANG INSPECTION |
0500 |
NO PROBLEM REPORT |
|
COMPLETE RH REPAIR, CASE TO INSULATION DEBOND TANG |
0500 |
PR-SR-RAC-050-0001 |
|
INSTALL. JOINT ROUNDING TOOL TO TANG |
0545 |
016° - 196° LOCATION |
|
"0" RINGS INSTALLED |
0910 |
|
|
CLOSEOUT PHOTOS TAKEN |
0915 |
|
|
REMOVE TOOL AND TAKE ROUNDNESS MEASUREMENT |
0935 |
ACCEPTABLE |
|
TANG ENGAGED |
1015 |
|
|
FIRST PIN INSTALLED |
1020 |
|
|
LAST PIN INSTALLED |
1030 |
|
|
LEAK CHECK COMPLETED |
1220 |
0.0 PSI DECAY |