Image Description - 0721-table2 A table is captioned “Table II. Sensitivities of Primitive Variables Uncertainties of Truss Structural Response”. The table shows sensitivity factors for several variables with respect to the response type. Sensitivity factors are identified in terms of geometry (width, length and height); load (vertical, longitudinal, end moment and couple); material property (modulus) and tube radii (outer and inner). Structural parameters used for evaluating the response are listed in the first column of the table. The response types include displacements in the X, Y, and Z directions; Axial forces in the top front, longerons (bottom batten, front vertical and rear diagonal); and first and second frequency modes. For a response type of displacement in the X-direction the sensitivity factors are 0.35 for geometry (width), 0.66 for geometry (length), less than 10 percent for geometry (height), 0.22 for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of displacement in the Y-direction the sensitivity factors are 0.18 for geometry (width), 0.69 for geometry (length), less than 10 percent for geometry (height), 0.36 for load (vertical), 0.16 for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of displacement in the Z-direction the sensitivity factors are 0.12 for geometry (width), 0.73 for geometry (length), less than 10 percent for geometry (height), 0.28 for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of displacement in the Z-direction (for the beam element only) the sensitivity factors are less than 10 percent for geometry (width), 0.76 for geometry (length), 0.34 for geometry (height), 0.34 for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of axial force (top front) the sensitivity factors are 0.24 for geometry (width), 0.44 for geometry (length), less than 10 percent for geometry (height), 0.35 for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of axial force (longeron bottom batten) the sensitivity factors are 0.39 for geometry (width), 0.28 for geometry (length), 0.14 for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), 0.56 for tube radius (outer), and 0.44 for tube radius (inner). For a response type of axial force (longeron front vertical) the sensitivity factors are less than 10 percent for geometry (width), less than 10 percent for geometry (length), less than 10 percent for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), 0.12 for material property (modulus), 0.76 for tube radius (outer), and 0.63 for tube radius (inner). For a response type of axial force (longeron rear diagonal) the sensitivity factors are 0.55 for geometry (width), 0.39 for geometry (length), less than 10 percent for geometry (height), 0.30 for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), less than 10 percent for tube radius (outer), and less than 10 percent for tube radius (inner). For a response type of frequency (mode 1) the sensitivity factors are less than 10 percent for geometry (width), 0.47 for geometry (length), less than 10 percent for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), 0.25 for tube radius (outer), and 0.19 for tube radius (inner). For a response type of frequency (mode 1 for the beam element only) the sensitivity factors are 0.23 for geometry (width), 0.30 for geometry (length), 0.11 for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), 0.30 for tube radius (outer), and 0.23 for tube radius (inner). For a response type of frequency (mode 2) the sensitivity factors are 0.17 for geometry (width), 0.39 for geometry (length), less than 10 percent for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), 0.32 for tube radius (outer), and 0.24 for tube radius (inner). For a response type of frequency (mode 2 for the beam element only) the sensitivity factors are less than 10 percent for geometry (width), 0.27 for geometry (length), 0.18 for geometry (height), less than 10 percent for load (vertical), less than 10 percent for load (longitudinal), less than 10 percent for load (end moment), less than 10 percent for load (couple), less than 10 percent for material property (modulus), 0.33 for tube radius (outer), and 0.25 for tube radius (inner).