Scientists and payload developers can get more information on International Space Station research facilities by contacting the
ISS Payloads Office or at 281-244-6187.
Group Activation Pack-Fluid Processing Apparatus (GAP-FPA)
04.26.13
OpNom:
Summary | Overview | Operations | Results | Publications | Imagery
Facility Summary
This content was provided by Stefanie Countryman, M.B.A., and is maintained in a database by the ISS Program Science Office.
Brief Summary
The Group Activation Pack-Fluid Processing Apparatus (GAP-FPA) is similar to a small test tube containing a glass barrel with a rubber septum in a LexanTM sheath. It has gas-permeable membranes; however, gas exchange is limited. The GAP-FPA allows sequential mixing of two or three fluids within a sterile environment.
Facility Manager(s)
Stefanie Countryman, M.B.A., University of Colorado, Boulder, CO, United States
Facility Representative(s)
Information Pending
Developer(s)
University of Colorado at Boulder, BioServe Space Technologies, Boulder, CO, United States
Sponsoring Space Agency
National Aeronautics and Space Administration (NASA)
Sponsoring Organization
Human Exploration and Operations Mission Directorate (HEOMD)
ISS Expedition Duration
September 2000 - April 2009
Expeditions Assigned
0,8,13,16,17,18
Previous ISS Missions
Thousands of GAP-FPAs have flown aboard the space shuttle, Progress, Mir and International Space Station.
Availability
Retired/Returned/Disposed
^ back to top
Facility Overview
- The Group Activation Pack-Fluid Processing Apparatus (GAP-FPA) is capable of mixing fluids in microgravity.
- The GAP-FPA can be used in a variety of biological studies, such as antibiotic-producing bacteria, yeast, and cell culture studies.
The Group Activation Pack-Fluid Processing Apparatus (GAP-FPA) is a test tube that allows controlled, sequential mixing of two or three fluids in microgravity. A total of 6.5-ml of fluid is contained inside a glass barrel (1.35 cm inner diameter x 11.7 cm) surrounded by a Lexan
TM sheath and initially can be isolated into three volumes by a rubber septum. A bypass in the glass barrel allows fluid to flow into an adjacent chamber as a plunger mechanism pushes the septum forward. Sets of eight FPAs can be housed in a GAP. Currently, four types of GAPs are used to support the FPAs; they are as follows:
- The Manual GAP provides a third level of fluid containment and allows eight FPAs to be processed simultaneously. Crewmembers manually activate the GAP by attaching a crank handle.
- The Automated GAP (auto-GAP) provides a third level of fluid containment and allows eight FPAs to be processed simultaneously using a direct-current (DC) motor drive mechanism to initiate and terminate experiments based on preprogrammed instructions. The auto-GAP can be housed within the Commercial Generic Bioprocessing Apparatus (CGBA) Isothermal Containment Module (ICM) v.1 and 2 for computer and thermal control.
- The Internal Motor GAP (IM-GAP) provides a third level of fluid containment and allows eight FPAs to be processed simultaneously. It uses an internal centerline DC-motor drive mechanism to initiate and terminate experiments based on preprogrammed instructions. The IM-GAP shell is constructed of aluminum to improve heat-transfer properties. The IM-GAP can be housed within CGBA ICM v.3 for computer and individual thermal control.
- The Gas Exchange GAP (GE-GAP) provides a third level of fluid containment and allows eight FPAs to be processed simultaneously when used in conjunction with an IM-GAP, or it can house a stack of nine 105-mm petri dishes. Like the IM-GAP, the GE-GAP's shell is constructed of aluminum to improve heat transfer properties. Openings in the wall, which are covered by gas-permeable membranes, allow passive gas exchange for the experiment samples. The GE-GAP is housed within the CGBA ICM v.3 for computer and individual thermal control.
The FPA has gas-permeable membranes that allow limited gas exchange. Each FPA has a total liquid volume of 6.5-ml and allows sequential mixing of two or three fluids in a sterile environment. Eight FPAs can be housed in an automated, motorized GAP. The Commercial Generic Bioprocessing Apparatus (CGBA) Isothermal Containment Module (ICM) v.4 and 5 can provide highly accurate temperature control between -10 and 37 °C. Eight areas with individually controlled temperature are available inside the CGBA when it is loaded with the GAP-FPA hardware. The CGBA ICM v.4 and 5 are fully equipped with data, video, and telemetry electronics to allow telescience remote operation and can be equipped with a number of bioprocessing inserts, including FPAs within the GAPs.
Operations
Facility Operations
The Commercial Generic Bioprocessing Apparatus (CGBA) Isothermal Containment Module (ICM) v.4 and 5 can provide highly accurate temperature control between -10 and 37 °C. Eight areas with individually controlled temperature are available inside the CGBA when it is loaded with the GAP-FPA hardware. The CGBA ICM v.4 and 5 are fully equipped with data, video, and telemetry electronics to allow telescience remote operation and can be equipped with a number of bioprocessing inserts, including FPAs within the GAPs.
^ back to top
Results/More Information
Information Pending
Results Publications
^ back to top
Ground Based Results Publications
^ back to top
ISS Patents
^ back to top
Related Publications
^ back to top
Related Websites
BioServe
NIH BioMed-ISS Meeting Video Presentation, 2009?GAP-FPA
NIH BioMed-ISS Meeting, 2009?GAP-FPA
^ back to top
Imagery
The Group Activation Pack-Fluid Processing Apparatus (GAP-FPA) is essentially a microgravity test tube that allows controlled, sequential mixing of two or three fluids in a weightless environment. Image courtesy of BioServe Space Technologies, University of Colorado - Boulder, Boulder, CO.
+ View Larger Image